ZP730-2P

Ziton series addressable optical detector
  • Responds to slow burning fires
  • EN54-7 and CPR certified
  • Analogue sensing - reduces false and unwanted alarms
  • Addressable - system knows the status and location of every sensor
  • Alarm verification, self test, auto contamination adjustment
View all

Related products

At a glance

Reliable sensing for most fire alarm applications

Designed for early response to slow burning, smoldering fires, the ZP730-2P is a Polar White, addressable smoke detector developed to provide reliable sensing for most fire alarm applications. The detector's proven stability in air movement associated with air conditioning systems has made it a popular selection for modern building interiors.

Operating on light scatter principles, the ZP730-2 fully meets the sensitivity requirements of EN54-7 and is approved by several international approval bodies.

Automatic self test

False and unwanted alarms are virtually eliminated - smoke levels are continuously sensed by the unit and transmitted via the ZP wiring loop as electronic signals. These are assessed and verified by the control panel prior to any alarm decision being taken.

Installed as part of a ZP addressable system, up to 127 sensing devices may be connected to each of the control panel loops. All loop devices incorporate switch settings enabling them to be assigned a unique address that is polled by the panel every two seconds.

Sensor sensitivity, calibration and self-test are carried out automatically by the ZP system. Removal or replacement of an incorrect sensing device will be identified by the system and shown as a fault. Sophisticated auto contamination adjustment compensates for any drift in performance due to dirt in the sensing chamber.

Locking base option

For ease of removal sensors plug into a range of base units by a simple twist and lock action. A site selectable option is provided to lock the sensor into its base. Once applied the unit can only be removed by means of a special tool.

A red LED indicator situated on the sensor molding flashes to indicate when the unit is in alarm. Space for address labels is provided on sensor and base moldings, ensuring units are replaced in their correct location and address numbers can be identified from floor level.

Details

  • Responds to slow burning fires
  • EN54-7 and CPR certified
  • Analogue sensing - reduces false and unwanted alarms
  • Addressable - system knows the status and location of every sensor
  • Alarm verification, self test, auto contamination adjustment

Technical specifications

General
Status indication
Alarm LED (red)
Compatibility
ZP7 addressable systems
Addressing method
DIP Switches
Electrical
Power supply type
Loop powered
Operating voltage
19.5 to 20.5 V
4 V (max. line loss)
Current consumption
<600 μA (quiescent)
<700 μA (active)
Detection
Detection principle
Photo electric light scatter
Sensitivity
Configurable (1.6%, 2.3%, 3.0%, 3.6% obs/m)
Coverage area
100 m²
Output
Output quantity
1
Output type and rating
Remote indicator
Programmable
No
Remote alarm output
Yes
Physical
Physical dimensions
106 x 52 mm (Ø x H)
Net weight
105 g (excluding base)
Colour
Signal white (RAL 9003)
Mounting type
Base mount
Material (body)
Moulded ABS
Environmental
Vandal proof
No
Operating temperature
-10 to +75°C
Storage temperature
-20 to +70°C
Relative humidity
20 to 95% noncondensing
Environment
Indoor
IP rating
IP32
Regulatory
Compliancy
CE
REACH
RoHS 3
WEEE
Certification
CPR
Standards
EN54-7
Environmental
EEC89/336