GS614
Shock sensor analyser
- Sensitivity setting
- Programmable pulse count, 1-9
- LED indication
- On-board voltage regulation
Related products
At a glance
Shock Sensor Analyser
The GS614 is a multicount analyser which in addition to the amplitude adjustment has a programmable 1-second count facility which allows the alarm to be activated after a series of small shocks are received at 1-second intervals. The counter is programmed for 2, 4, 5 or 8 counts within a fixed time period of 30 seconds. If the programmed number of small shocks is received, the alarm activates, or if one shock larger than the setting on the potentiometer is received, the alarm will activate.
Up to 12 shock sensors can be connected to one analyser (IS 199 standard).
Up to 12 shock sensors can be connected to one analyser (IS 199 standard).
Details
- Sensitivity setting
- Programmable pulse count, 1-9
- LED indication
- On-board voltage regulation
Technical specifications
| General | ||
|---|---|---|
| Product type |
Shock sensor analyser
|
|
| Alarm contact |
12 VDC, 1 A
|
|
| Wired/wireless | ||
|---|---|---|
| Wired-wireless |
Wired
|
|
| Electrical | ||
|---|---|---|
| Operating voltage |
10-15 VDC
|
|
| Current consumption |
10 mA (quiescent)
50 mA (alarm)
|
|
| Environmental | ||
|---|---|---|
| Operating temperature |
-40 to +50°C
|
|
Downloads
All downloadsDatasheet
Installation sheet
Certificates